| 耐高(gāo)溫(wēn)(剛(gāng)體(tǐ))鋼(gāng)體(tǐ)滑觸(chù)綫(xiàn) 一:HXPnL-T,HXPnL-TⅡ,HXPnL-TⅢ係列鋼(gāng)體滑綫由銅(tóng)導軌,導軌支架,絕(jué)緣子組件以(yǐ)及外(wài)置式集電器等(děng)組件組(zǔ)合(hé)而(ér)成(chéng),由於(yú)該(gāi)產品具有電(diàn)流大(dà),耐(nài)高(gāo)溫,抗(kàng)腐蝕等特點,因此(cǐ)被(bèi)廣(guǎng)泛(fàn)應用於冶金,造(zào)船(chuán),港口等(děng)行(háng)業(yè). | HXPnL-T係列鋼(gāng)體滑(huá)綫 HXPnL-T Serise steel collector bar | | 型號(hào)規格 Type & spec | 滑觸綫截麵尺寸(mm)Busbar size (mm) | 載流量(liáng)(A) Current(A) | 適(shì)配(pèi)外置式集電(diàn)器 Suit able current collenctor | | A | B | C | | HXPnL-T-85/300 | 48 | 56 | 13.42 | 300 | TJD-600 | | HXPnL-T-110/400 | 50 | 56 | 14.11 | 400 | TJD-600 | | HXPnL-T-170/500 | 55 | 56 | 15.88 | 500 | TJD-600 | | HXPnL-T-240/700 | 58 | 56 | 16.93 | 700 | TJD-600 | | HXPnL-T-320/900 | 63 | 56 | 18.7 | 900 | TJD-600 | | HXPnL-TⅡ-170/1000 | 65 | 80 | 46 | 1000 | TJD-1200 | | HXPnL-TⅡ-240/1300 | 68 | 80 | 46 | 1300 | TJD-1200 | | HXPnL-TⅡ-320/1900 | 73 | 80 | 50 | 1900 | TJD-1200 | | 注(zhù):滑觸(chù)綫(xiàn)標準(zhǔn)長度(dù):6m。 Note:standard busbar length 6m. |    一(yī),產品特點 本產品(pǐn)由(yóu)梯(tī)型(xíng)銅棒和槽鋼(gāng)或由(yóu)“T”型(xíng)銅排和(hé)槽(cáo)型鋁結合相構成(chéng)。用高強度(dù)絕(jué)緣(yuán)子作(zuò)支撐(chēng),從而組(zǔ)成(chéng)向各種起重機(jī)械設(shè)備(bèi)饋電的移動(dòng)滑(huá)觸(chù)綫。本產(chǎn)品有如下(xià)特點(diǎn): 1,運(yùn)行可(kě)靠,絕(jué)不發生電源中斷(duàn)故(gù)障。 2,可使用於(yú)高(gāo)溫(wēn),高粉(fěn)塵(chén),高腐(fǔ)蝕(shí)氣(qì)體等(děng)惡劣環境(jìng)。 3,機(jī)械強(qiáng)度大,不易彎(wān)曲變形,能(néng)耐受(shòu)*的(dí)短路衝(chōng)擊(jī)電流。 4,可(kě)根據用(yòng)戶(hù)需(xū)要設定載(zǎi)流量(liáng),zui大可(kě)達3000A以上,電壓等級可達到(dào)5KV以上(shàng)。 5,采用銅(tóng)或銅鋁(lǚ)導體(tǐ),可(kě)大(dà)幅度(dù)降低導綫(xiàn)電能損(sǔn)耗(hào)。 6,添加輔(fǔ)助(zhù)電纜後(hòu),可(kě)組成低阻抗(kàng)滑(huá)觸(chù)綫,導綫阻抗成倍(bèi)降低(dī)。 7,布(bù)綫(xiàn)可在(zài)上部或下(xià)部滑觸(chù)。 8,JGH-“I”型滑觸綫更有散(sàn)熱麵特大,結構緊湊(còu)簡單,安(ān)裝(zhuāng)維(wéi)修(xiū)方(fāng)便(biàn)等優點。 二(èr),產品(pǐn)型號與規格 鋼體滑觸綫型號,規(guī)格及(jí)額定電流值 | 型(xíng)號(hào) | 標(biāo)稱(chēng)截麵 | 額定(dìng)電壓(A) | 重(zhòng)量(liáng)(Kg/6m) | | JGH-85 | 85 | 500 | 24.3 | | JGH-110 | 110 | 600 | 25.9 | | JGH-170 | 170 | 800 | 29.4 | | JGH-240 | 240 | 1000 | 46.1 | | JGH-320 | 320 | 1200 | 50.4 | | JGH-170Ⅱ | 2x170 | 1300 | 53.9 | | JGH-240Ⅱ | 2x240 | 1800 | 62.2 | | JGH-320Ⅱ | 2x320 | 2200 | 68.8 | | 注(zhù):滑觸綫標(biāo)準長度:6m,可根據用(yòng)戶需(xū)求設置載(zǎi)流(liú)量,zui大(dà)可(kě)達3000A以上(shàng)。 | | 型號(hào) | 標稱(chēng)截(jié)麵 | 額定電壓(A) | 重量(liáng)(Kg/6m) | | JGHI-10 | 85 | 500 | 24.3 | | JGHI-110 | 110 | 600 | 25.9 | | JGHI-170 | 170 | 800 | 29.4 | | JGHI-240 | 240 | 1000 | 46.1 | | JGHI-320 | 320 | 1200 | 50.4 | | JGHI-170Ⅱ | 2x170 | 1300 | 53.9 | | JGHI-240Ⅱ | 2x240 | 1800 | 62.2 | | JGHI-320Ⅱ | 2x320 | 2200 | 68.8 | 鋼體滑(huá)觸綫(xiàn)一(yī)般情況下(xià)按(àn)6m定尺(chǐ)長(cháng)度供(gōng)貨。 鋼(gāng)體滑(huá)觸(chù)綫絕(jué)緣(yuán)支(zhī)架(jià)安(ān)裝(zhuāng)間(jiān)距一(yī)般(bān)為3m 滑觸綫(xiàn)分(fēn)為單(dān)綫(xiàn)式和雙綫平等饋電(diàn)式兩種(zhǒng),除(chú)雙綫平等式以JGH-□II表(biǎo)示外,單(dān)綫式不另(lìng)加表注,其(qí)斷(duàn)麵如下(xià): 三,鋼(gāng)體滑(huá)觸(chù)綫係列配套件(jiàn) D集電器 | | | 型號 | JDG-I | JDG-II | | 額定電(diàn)流(A) | 600 | 1200 | | 接觸(chù)壓(yā)力(lì)(kg) | 6±2 | 10±2 | | 電壓(V) | 600 | 600-300 | | 滑塊材料 | 粉末(mò)合金(jīn) | 粉(fěn)末合(hé)金 | | 四(sì),鋼(gāng)體滑觸綫(xiàn)的連(lián)接 滑觸(chù)綫的(dí)連(lián)接如下圖所示: 連(lián)接時(shí),將(jiāng)兩(liǎng)段支(zhī)架,通過(guò)內(nèi)部的(dí)鋼芯用螺(luó)栓(shuān)連接,銅導體則(zé)用(yòng)二塊(kuài)長夾(jiā)板,夾(jiā)緊在(zài)支架(jià)上,為(wéi)了(liǎo)防止剛體因(yīn)溫度變(biàn)化引(yǐn)起(qǐ)的(dí)膨脹(zhàng),安裝時在連接處(chǔ)應留有(yǒu)間(jiān)隙,間(jiān)隙的(dí)尺(chǐ)寸見下表(biǎo): | 工作場地的周圍(wéi)溫度 | 30°C | 40°C | 60°C | 70°C | | 間隙(xì)尺寸(cùn) | 3-5mm | 5-7mm | 7-9mm | 10-15mm | 予留間隙(xì)的(dí)尺寸跟安裝時的環(huán)境(jìng)溫(wēn)度有關(guān),一般冬季(jì)安裝時(shí)取高值,夏天安(ān)裝時取(qǔ)低值。 五(wǔ),滑(huá)觸綫(xiàn)的安(ān)裝(zhuāng) 滑觸(chù)綫的安(ān)裝方式,一般(bān)常用(yòng)的(dí)為上部(bù)滑觸和(hé)下部滑觸二種,也(yě)可根(gēn)據用(yòng)戶(hù)要求(qiú),采用其它安裝方(fāng)式。 滑觸(chù)綫的安裝支(zhī)架一般為3m一個,特殊情(qíng)況(kuàng)亦(yì)可采(cǎi)取加強(qiáng)措(cuò)施(shī)適當擴大距(jù)離,三(sān)根(gēn)滑(huá)觸(chù)綫之間(jiān)的相間距離為400mm,如為(wéi)低阻(zǔ)抗(kàng)滑(huá)觸綫,相間距離可(kě)擴(kuò)大(dà)到(dào)450mm。 六,鋼體滑觸(chù)綫的設計數據及(jí)計(jì)算方式 1,滑觸(chù)綫阻(zǔ)抗值及(jí)100A-100m時的綫路(lù)電(diàn)壓降值(zhí)(使用電(diàn)壓為(wéi)380V,COS為0.8時) | 滑觸綫(xiàn)規(guī)格(gé) mm2 | 相(xiāng)間(jiān)距離 mm | 在90°C時(shí)阻(zǔ)降(jiàng)值(zhí)Z Ω/Km | 100A-100m時綫(xiàn)路電壓(yā)降 | | u(V) | u% | | 85 | 200 | 0.3629 | 6.29V | 1.65% | | 300 | 0.3813 | 6060V | 1.73% | | 400 | 0.3946 | 6084V | 1.80% | | 110 | 200 | 0.3202 | 5.55V | 1.16% | | 300 | 0.3404 | 5.90V | 1.55% | | 400 | 0.3552 | 6.15V | 1.62% | | 170 | 200 | 0.2690 | 4.66V | 1.23% | | 300 | 0.2915 | 5.05V | 1.33% | | 400 | 0.3078 | 5.33V | 1.40% | | 240 | 200 | 0.2459 | 4.26V | 1.12% | | 300 | 0.2716 | 4.70V | 1.24% | | 400 | 0.2857 | 4.95V | 1.30% | | 320 | 200 | 0.2328 | 4.03V | 1.06% | | 300 | 0.2596 | 4.50V | 1.18% | | 400 | 0.2741 | 4.75V | 1.25% | | 2×170 | 200 | 0.2076 | 3.60V | 0.95% | | 300 | 0.2319 | 4.02V | 1.06% | | 400 | 0.2493 | 4.32V | 1.14% | | 2×240 | 200 | 0.1976 | 3.42V | 0.90% | | 300 | 0.2249 | 3.90V | 1.03% | | 400 | 0.2416 | 4.19V | 1.10% | | 2×320 | 200 | 0.1932 | 3.35V | 0.88% | | 300 | 0.2178 | 3.77V | 0.99% | | 400 | 0.2046 | 4.06V | 1.07% | 2,滑觸綫在(zài)短路(lù)時耐受電(diàn)流值(KA)(安裝支架(jià)間(jiān)距為(wéi)3m時) | 滑(huá)觸綫(xiàn)規格(gé) mm2 | 滑觸綫(xiàn)三相(xiāng)平(píng)放時相間(jiān)距(jù)離為(wéi) | 滑(huá)觸(chù)綫三相豎(shù)放時(shí)相間距離(lí)為(wéi) | | 200mm | 300mm | 400mm | 200mm | 300mm | 400mm | | 85 | 22 | 26 | 31 | 29 | 35 | 41 | | 110 | 23 | 27 | 32 | 30 | 36 | 42 | | 170 | 25 | 30 | 35 | 32 | 39 | 45 | | 240 | 41 | >50 | >50 | >50 | >50 | >50 | | 320 | 43 | | 2×170 | >50 | | 2×240 | | 2×320 | 3,鋼體滑觸綫(xiàn)的撓(náo)度量(mm) | 滑觸綫規格 mm2 | 滑(huá)觸綫(xiàn)三相豎放(fàng)時(shí),支架(jià)間距(jù)離(lí)為(wéi) | 滑觸綫三(sān)相平(píng)放時,支架間(jiān)距離為(wéi) | | 2m | 3m | 4m | 5m | 2m | 3m | 4m | 5m | | 85 | 0.28 | 1.44 | 4.6 | 11.1 | 0.33 | 1.62 | 5.14 | 12.6 | | 110 | 0.31 | 1.52 | 4.8 | 11.8 | 0.35 | 1.72 | 5.44 | 13.2 | | 170 | 0.35 | 1.73 | 5.4 | 13.5 | 0.38 | 1.96 | 6.17 | 15.0 | | 240 | 0.16 | 0.84 | 2.3 | 5.4 | 0.20 | 1.08 | 3.20 | 7.8 | | 320 | 0.19 | 0.96 | 2.4 | 5.9 | 0.24 | 1.20 | 3.60 | 8.4 | | 2×170 | 0.22 | 1.09 | 3.5 | 8.5 | 0.17 | 0.86 | 2.70 | 6.6 | | 2×240 | 0.16 | 0.79 | 2.5 | 6.1 | 0.22 | 1.12 | 3.50 | 8.5 | | 2×320 | 0.18 | 0.91 | 2.9 | 7.1 | 0.25 | 1.28 | 4.10 | 10.0 | 4,負(fù)荷電(diàn)流計算(suàn) 滑(huá)觸(chù)綫負荷電流計算方(fāng)法,過去(qù)采(cǎi)用(yòng)二項公式(shì)計(jì)算(suàn)。現介紹國外(wài)多數資料中(zhōng)采用的計算方式如下:即根據(jù)起重(zhòng)機上安裝的有(yǒu)可能同(tóng)時(shí)運(yùn)轉(zhuǎn)的電動機(jī)和額定(dìng)電(diàn)流(liú)乘以(yǐ)暫載係數(shù)和多台起重機(jī)的同時(shí)係(xì)數。 負荷電(diàn)流(I)=所有工作電(diàn)動機額(é)定(dìng)電流(1H)×暫載(zǎi)係(xì)數(shù)(FED)×同時係數(F) FED暫(zàn)載係(xì)數按下表確定(dìng):(多(duō)台(tái)起重(zhòng)機同時工(gōng)作係數:F取(qǔ)0.4-0.7) | 暫載(zǎi)率(ED) | 暫載率(FED) | | 100% | 1.00 | | 80% | 0.90 | | 60% | 0.78 | | 50% | 0.71 | | 40% | 0.63 | 5,滑觸綫路的電(diàn)壓(yā)降問(wèn)題(tí) 過去(qù)設(shè)計滑觸綫路(lù)時,采用zui大(dà)電流(liú)來檢(jiǎn)驗電壓(yā)降(jiàng)。即從(cóng)低壓(yā)屏上的(dí)饋電形狀(zhuàng)到滑觸(chù)綫取(qǔ)末端,包括供電電(diàn)纜在內的電壓降(jiàng)不得(dé)超過12%,也就是滑觸(chù)綫(xiàn)和(hé)供電(diàn)綫路當(dāng)作(zuò)一個(gè)整體來考慮,在(zài)滿足(zú)電壓降的要求下(xià),務使(shǐ)投資(zī)zui少(shǎo)。隨(suí)著近年來引(yǐn)進工程(chéng)增(zēng)多(duō),綜合(hé)國(guó)外(wài)資料,國外(wài)一般都以(yǐ)負荷計(jì)算電(diàn)流(liú)來檢驗(yàn)電(diàn)壓(yā)降,包(bāo)括供(gōng)電綫(xiàn)路(lù)在(zài)內(nèi)到滑觸綫zui末的電壓降值(zhí)不得(dé)超過5%。 電壓(yā)計(jì)算(suàn)公式: u=√ 3 × I×I×Z 或(huò) u=√ 3 × I×I×(RCOSρ+XSinΨ) 式中: u=電(diàn)壓(yā)降(V), I=負(fù)荷計算電(diàn)流(liú)(V), R=電(diàn)阻(zǔ)(Ω/km) X=電感(gǎn)(Ω/km), Z=阻抗(Ω/km), L=滑(huá)觸綫諸長度(m) 滑觸(chù)綫計算(suàn)長(cháng)度(dù)方(fāng)式:為(wéi)滑觸(chù)綫全(quán)長(m) 在(zài)滑(huá)觸(chù)綫端部供電時:I=L 在(zài)滑(huá)觸綫(xiàn)中(zhōng)部供電時:I=L/2 在滑(huá)觸綫兩端部同時供(gōng)電(diàn)時(shí):I=L/4 在(zài)滑觸綫(xiàn)兩(liǎng)端端部距L/6處(chǔ)供電(diàn)時:I=L/6 七,低阻抗滑觸(chù)綫 近代(dài)工業中(zhōng),起(qǐ)重(zhòng)機(jī)噸位日益(yì)增大(dà),運(yùn)行(háng)距離也(yě)愈來(lái)愈長,如何處(chǔ)理滑觸(chù)綫(xiàn)上的(dí)電(diàn)壓(yā)降不(bù)超(chāo)過允許值(zhí)問題(tí),需要設(shè)計過(guò)程(chéng)中(zhōng)妥(tuǒ)善解決(jué)。過(guò)去解(jiě)決(jué)電壓(yā)降(jiàng)過大(dà)的(dí)方法(fǎ),不外乎采(cǎi)用(yòng):加大(dà)滑觸綫和供(gōng)電綫(xiàn)路(lù)的(dí)截(jié)麵(miàn);增加滑觸綫上的供電點數(shù);縮小(xiǎo)三根滑(huá)觸(chù)綫之間的(dí)相間距(jù)離(lí)等等,但這些(xiē)措(cuò)施往(wǎng)往收效甚(shèn)微(wēi)或(huò)很不(bù)經(jīng)濟(jì),這是(shì)因(yīn)為(wéi)滑觸綫路中的電抗(kàng)值難以降(jiàng)低(dī),所以首先要(yào)解決如(rú)何(hé)減少(shǎo)滑(huá)觸綫路(lù)上的(dí)電抗(kàng)值著(zhuó)手。本(běn)廠同(tóng)有關(guān)設(shè)計單位一(yī)起,研(yán)究(jiū)國外(wài)資料(liào),在剛(gāng)體(tǐ)滑觸(chù)綫(xiàn)上的基(jī)礎上(shàng),添加兩根輔(fǔ)助(zhù)電(diàn)纜(lǎn),組成(chéng)低阻(zǔ)抗滑觸(chù)綫後,可(kě)使綫(xiàn)路阻(zǔ)抗值成(chéng)倍地降低(根據不(bù)同(tóng)規(guī)格的剛(gāng)體(tǐ)添加不同(tóng)截(jié)麵的電(diàn)纜後(hòu),其阻抗(kàng)值可以降低到原來的1/2-1/3) |